[breadcrumb]

REFORM

UL4 MIST COLLECTOR FOR REFORM GRINDERS

Machine Information

FEATURES

The moisture caused during the grinding operation is very often felt to be troublesome and disturbing, like-wise the deposition of oilmist on the surrounding machine parts. The Reform UL exhaust unit is mounted to the backside of the machine, travelling with the grinding carriage. Exhausting occurs directly at the grinding area, therefore a spreading of mist is avoided.

ADVANTAGES

  • Cleaner air in your working area
  • Return of coolant to grinder
  • Reduction in heat loss as air is recirculated in grinding room

FUNCTION

The oilmist is exhausted by a blower ventilator A, passing a compact pocket filter B, (and Chevron pre-filter on mist pack) where moisture and dust are separated in the filter layers. With help of the suitably shaped bottom of the unit, the extracted liquid is collected and can be returned to the machine over an outlet hole C. The utilized special pocket filters B are adjusted to the ventilator power and have been tested under laboratory conditions.

SPECIFICATIONS

Range of application: Type 51, Type 5, Type 4
Dimension of unit (LxWxH) 15.7” (400mm) x 13.4” (340mm) x 27.2” (690mm)
Suction Hose Ø 2 ¾” (2 x 70mm)
Outlet Hose Ø R 3/8”
Air Capacity 400 CFM
Weight 62 lbs.
Electrics 208/230/460 or 575/3/60 less starter
Complete with Nozzle, hosing & mounting brackets

Category: